Serum/plasma stability
Measurement
ATLXM0000573
Peptide
ATLPC0025294
→
Measured material
Specific molecular form
Endpoint
Serum/plasma stability
→
ADMET domain
Metabolic & Proteolytic Stability
Value
67 minutes
Normalized value
4,020 seconds
Evidence role
Comparable: structured measurement intended for within-endpoint comparison when assay context matches
Assay / model
RP-HPLC · mouse · Mouse serum
Condition
Dose/window: 100 μg/mL · Mouse serum proteases · in vitro
Scientific source
DOI: 10.1034/j.1399-3011.1999.00094.x